Unfortunately, I need to graph uptime values, because that is format of the
object that Network Appliance choose for their CPU load value.
Actually, NetApps provide the number of timeticks the Filer spent doing
work, since SNMP start. And since the BER.pm module would return timeticks
as a formatted string, I needed a way to have it returned as a numeric
value.
Jeff Allen wrote:
> From: Jeff Allen <jra@corp.webtv.net>
>
> I'd just like to go down on the record as saying WebTV does not fetch
> and graph uptimes, so I don't care or have much interest in how we
> solve the problem of formatting the returned string.
>
> I'll take the first patch that implements something people generally
> think is a good solution and integrate that, and it should be a solved
> problem going forward. So, now you guys just need to agree on the best
> solution... :)
>
> --
> Jeff R. Allen | jra@corp.webtv.net
> WebTV Service Engineering | http://www.munitions.com/~jra
>
> --------------------------- ONElist Sponsor ----------------------------
>
> Who is the most visited e-mail list community Web Service?
> http://www.onelist.com
> ONElist.com - where more than 20 million e-mails are exchanged each day!
>
> ------------------------------------------------------------------------
-- Matthew Lee Stier * Fujitsu Network Communications Unix Systems Administrator | Two Blue Hill Plaza Ph: 914-731-2097 Fx: 914-731-2011 | Sixth Floor Matthew.Stier@fnc.fujitsu.com * Pearl River, NY 10965
This archive was generated by hypermail 2b29 : Mon Mar 06 2000 - 19:00:55 PST